Place of use
These cables are used in transmission of VGA video signals in multipurpose media applicatios. They have high resolution and low attenuation values.
Inner Conductor | 7x0,16 mmØ Electrolytic Stranded Tinned Copper |
Dielectric | 2,10 mmØ Foam Polyethylene |
1.Screen | %100 Coverage Tinned Copper Wrap |
2.Screen | %100 Coverage AL-PES Tape |
Coaxial Sheath | 3,05 mmØ PVC (Red, Green, Blue,Black,White) |
3.Screen | %100 Coverage AL-PES Tape |
Drain Wire | 7x0,25 mmØ Electrolytic Stranded Tinned Copper |
Outer Sheath | 10,50 mmØ PVC Compaund, RAL 5015 Black |
Product Code | Dimension and Weights | Electrical Properties | |||||||||
Nominal Cross Section | Overall Diemeter ( ~ ) |
Net Weight ( ~ ) |
Standart Lenght | Max. Dc Conductor Resistance at 20◦ C | Current Carrying Capacity | ||||||
In Ground at 20° C | On Air at 30° C |
MUTUAL CAPACITANCE | VELOCITY OF PROPAGATION | OPERATING VOLTAGE | IMPEDANCE | BENDING RADIUS | TEMPERATURE RANGE | FLAME RETARDANT TEST |
57 pF/m | 78 % | 1 kV | 75±3 Ω | 15x D mm | - 30ºC+70ºC | IEC 60332-1-2 VDE 0482-332-1-2 EN 60332-1-2 |